A4J30 – GOULD 30A 600V FAST ACTING FUSE
The A4J30 – GOULD 30A 600V Fast Acting Fuse is designed for quick response to overcurrent situations, protecting your electrical systems from damage. With a rated current of 30 amps and a voltage of 600 volts, this reliable fuse ensures optimal performance and safety, making it ideal for various applications.
| Brand | Gould |
|---|---|
| Amperage | 30 A |
| Voltage | 600V |
| Interrupting Rating | 200 kA |
| Frame / Series | A4J |
| Catalogue # | A4J30 |
The Gould A4J30 is a Class J, 30A 600V fast-acting fuse with a 200kA interrupting rating. Class J fuses require a Class J-rated fuse holder or fused disconnect — they are not interchangeable with Class H, K, or other non-Class-J blocks. Compatible holders include Class J fuseholders and safety switches rated for 600V Class J fuses from manufacturers such as Gould/Ferraz Shawmut, Eaton/Bussmann, and Littelfuse.
- Direct replacements: Functionally equivalent Class J 30A 600V fast-acting fuses from Ferraz Shawmut, Littelfuse (JLLN-030), or Eaton/Bussmann (JKS-30) may be used where accepted by the authority having jurisdiction.
- Note: Verify your holder or disconnect is rated for Class J fast-acting fuses at 600V and 200kA. Send us your holder or equipment model and we'll confirm compatibility.
The A4J30 is a Class J fuse, which requires a Class J-rated fuse holder or fused disconnect rated for 600V. Class J fuses have a specific blade/ferrule geometry that prevents them from being installed in non-Class-J holders, ensuring the correct protection level is maintained.
Gould fuses (later branded Ferraz Shawmut) can be hard to source as new stock, but Northern Breaker Group specialises in obsolete and hard-to-find electrical components. We can supply original Gould/Ferraz Shawmut stock where available, or identify a functionally equivalent Class J 30A 600V fast-acting replacement from Littelfuse or Eaton/Bussmann. Contact us or visit one of our Calgary, Edmonton, or Vancouver counters for availability.
Fast-acting Class J fuses like the A4J30 respond almost instantaneously to overcurrent conditions, making them ideal for protecting equipment that does not produce high inrush currents (e.g., resistive loads, transformers with external inrush protection, or semiconductor circuits). Time-delay Class J fuses are better suited for motor circuits, which draw high inrush current on start-up. If you're replacing an existing fuse, match the type (fast-acting vs. time-delay) indicated on your equipment's nameplate or drawings.
Contact Northern Breaker Group



Reviews
There are no reviews yet.