AJT25 – GOULD 25A 600V CLASS J TIME DELAY FUSE
The AJT25 – Gould 25A 600V Class J Time Delay Fuse is designed for reliable overcurrent protection in industrial applications. With its time-delay feature, it accommodates temporary inrush currents, ensuring optimal performance and longevity. Ideal for various equipment, this fuse provides safety and efficiency, making it a trusted choice for your electrical needs.
| Brand | Gould |
|---|---|
| Amperage | 25 A |
| Voltage | 600V |
| Frame / Series | AJT |
| Catalogue # | AJT25 |
The Gould AJT25 is a Class J, 25A 600V time-delay fuse designed to fit any Class J fuse holder or fusible disconnect rated for 600V — including holders from Eaton/Bussmann, Mersen (Ferraz Shawmut), and Siemens. Its time-delay characteristic makes it well suited for protecting motors, transformers, and other inductive loads where harmless inrush currents must be tolerated without nuisance blowing.
- Direct form-and-fit replacements include the Eaton/Bussmann LPJ-25SP and Mersen AJT25 (same series, rebranded).
- Confirm your holder or disconnect is rated Class J, 600V, 25A or higher before installation.
Not sure if this fuse matches your holder or equipment? Send us your holder/disconnect model and we'll confirm compatibility.
A Class J time-delay fuse like the AJT25 is designed to carry temporary overload currents — such as motor start-up inrush — for a short period without blowing, while still providing fast, current-limiting protection under true short-circuit conditions. A fast-acting Class J fuse offers no intentional time delay and may blow on harmless inrush currents, making time-delay types the preferred choice for motor and transformer branch circuits.
Yes — Class J is a standardized UL/CSA fuse class, so the Gould AJT25 is dimensionally and electrically interchangeable with other manufacturers' Class J time-delay fuses of the same rating (25A, 600V), such as the Eaton/Bussmann LPJ-25SP or Mersen AJT25. Always verify the time-delay characteristic matches your application requirements before substituting.
Yes — the Gould AJT25 carries both UL and CSA certification, making it acceptable for use under the Canadian Electrical Code (CEC). It is rated 600V and 25A, covering the full voltage range common in Canadian single- and three-phase industrial systems. Always ensure the fuse rating matches the conductor size and equipment overcurrent protection requirements specified in your CEC installation.
Related Products
Contact Northern Breaker Group



Reviews
There are no reviews yet.