ATQR2 – GOULD 2A 600V CLASS CC TIME DELAY FUSE

2A · 600V

The ATQR2 – Gould 2A 600V Class CC Time Delay Fuse is designed to provide reliable protection for your electrical circuits. Featuring a time delay characteristic, this fuse allows for brief overload conditions without blowing, ensuring smooth operation. Ideal for a variety of applications, it guarantees safety and durability in demanding environments.

Add to Quote
SKU GOUATQR2 Categories ,
Specifications
BrandGould
Amperage2 A
Voltage600V
Interrupting Rating200 kA
Frame / SeriesATQR
Catalogue #ATQR2
Compatible Holders & Replacements

The Gould ATQR2 is a Class CC, 2A 600V time-delay fuse with a 200kA interrupting rating, built to the standardized Class CC form factor (10mm × 38mm / 13/32″ × 1-1/2″). It mounts in any Class CC–rated fuse holder or fusible disconnect from manufacturers such as Gould/Ferraz Shawmut, Littelfuse, Bussmann, and Mersen — provided the holder is rated for 600V and the required ampacity.

  • Direct time-delay replacements: Bussmann ATQR2, Littelfuse CCMR2, Mersen ATQR2 (verify rating marks before substituting)
  • Holder compatibility: Class CC finger-safe holders (e.g., Gould/Ferraz CH series, Bussmann HEB/HEX series) rated ≥ 600V and ≥ 2A

Not sure which holder or equivalent cross-reference fits your installation? Send us your holder model or equipment details and we'll confirm the right fit.

The ATQR2's time-delay design allows it to tolerate brief, harmless overload surges — such as motor inrush currents or transformer energizing peaks — without nuisance blowing. It still responds quickly to sustained overloads and short-circuit faults, providing dependable protection without unnecessary downtime.

Gould's fuse lines were acquired by Ferraz Shawmut and later Mersen, so the ATQR2 designation may appear under different branding. Functionally identical Class CC 2A 600V time-delay replacements are available from Bussmann (ATQR2) and Littelfuse (CCMR2). Northern Breaker Group specializes in obsolete and hard-to-find fuses — contact us and we'll source the right unit for you.

While a fast-acting Class CC fuse will physically fit the same Class CC holder, substituting it for a time-delay fuse is not recommended without an engineering review. Fast-acting fuses will not ride through normal inrush currents and may cause nuisance tripping. Always match the fuse type (time-delay vs. fast-acting) to the original specification for your equipment.

Same-Day Pickup
Calgary · Edmonton · Vancouver
Unmatched Experience
Electrical product experts
50,000+ Products
50+ years in the trade
Ships Canada-Wide
From our Western counters
Request a Quote

Related Products

Contact Northern Breaker Group

Experience the advantage of working with Canada's fastest growing electrical supply network—where local expertise meets national capabilities.
Whether you’re a contractor needing same-day pickup in Calgary, an facility manager sourcing obsolete parts in Edmonton, or a Vancouver electrician requiring marine-rated components, Northern Breaker Group is your trusted electrical supply partner.

For General Inquiries:

Visit any of our three locations or use our online quote system to connect with the Northern Breaker Group network.

Reach out to us today to discuss your needs.