CH230GFT – EATON 2P30A 240V PUSH IN BREAKER GFCI 5MA

GFCI · 30A · 2-Pole · 240V · Plug-In

The CH230GFT by Eaton is a reliable 2-pole, 30 Amp, 240V push-in GFCI breaker with a 5mA trip sensitivity. Designed for enhanced safety, it protects against ground faults in residential and commercial applications. Easy to install, this breaker ensures optimal performance for your electrical systems, including hot tub installations.

Add to Quote
SKU ETNCH230GFT Categories , ,
Specifications
BrandEaton
TypeGFCI / Ground-Fault
Amperage30 A
Poles2-Pole
Voltage240V
Interrupting Rating10 kA
MountingPlug-In
Frame / SeriesCH
Catalogue #CH230GFT
Panel Compatibility

The Eaton CH230GFT is a plug-in breaker from Eaton's CH (Type-CH) series, designed to install in Eaton CH-style loadcentres and panelboards. It occupies two pole spaces and is rated 30A / 240V / 10kA interrupting capacity, making it well-suited for dedicated branch circuits such as hot tubs, GFCI-protected spa equipment, and other double-pole 240V loads requiring 5mA ground-fault protection.

Not compatible with Eaton BR-series or other manufacturers' panels. Send us your panel model and we'll confirm fitment.

Yes — the CH230GFT is a popular choice for hot tub and spa circuits. It provides the 2-pole, 30A, 240V protection those loads require, and its 5mA GFCI sensitivity meets the Canadian Electrical Code (CEC) requirement for Class A ground-fault protection on hydromassage bathtub and spa circuits. Always verify your local inspection requirements before installation.

The CH230GFT includes built-in Class A GFCI protection at a 5mA trip threshold, which the standard CH230 does not. This means the GFT model will trip and cut power if it detects a ground-fault current as low as 5mA — providing personnel protection in addition to overcurrent protection. The physical size and plug-in installation method are the same.

Nuisance tripping on a GFCI breaker is usually caused by a wiring issue rather than a defective breaker. Common causes include the neutral load wire being connected to the panel neutral bar instead of the breaker's pigtail terminal, shared neutrals on the circuit, or a genuine ground fault in the connected equipment. Check that the white load wire connects only to the breaker's neutral terminal and that no other circuits share the neutral. If the breaker still trips with no load connected, it may need replacement — contact us and we can help source a verified unit.

Same-Day Pickup
Calgary · Edmonton · Vancouver
Unmatched Experience
Electrical product experts
50,000+ Products
50+ years in the trade
Ships Canada-Wide
From our Western counters
Request a Quote

Related Products

Contact Northern Breaker Group

Experience the advantage of working with Canada's fastest growing electrical supply network—where local expertise meets national capabilities.
Whether you’re a contractor needing same-day pickup in Calgary, an facility manager sourcing obsolete parts in Edmonton, or a Vancouver electrician requiring marine-rated components, Northern Breaker Group is your trusted electrical supply partner.

For General Inquiries:

Visit any of our three locations or use our online quote system to connect with the Northern Breaker Group network.

Reach out to us today to discuss your needs.