The EATON 72CCT 225A 347/600V MLO Panel is a complete solution designed for robust electrical distribution. Featuring a main lug-only configuration, it supports a maximum rating of 225 amps. Ideal for commercial applications, this panel ensures reliable performance, safety, and efficiency for your electrical system needs.
| Brand | Eaton |
|---|---|
| Amperage | 225 A |
| Voltage | 347/600V |
| Catalogue # | ETNFPP2AL4A272I |
The Eaton ETNFPP2AL4A272I is a 72-circuit, 225A, 347/600V Main Lug Only (MLO) panelboard, designed for commercial and light-industrial electrical distribution across Canadian three-phase systems. As an MLO configuration, it requires a separately installed upstream main disconnect or breaker to provide overcurrent protection for the panel. It is compatible with Eaton CH (Type-CH) and bolt-on style breakers rated for 347/600V service, supporting up to 72 circuit positions. If you need to confirm breaker compatibility, branch breaker sizing, or suitability for your specific installation, send us your project details and we'll confirm the right fit.
MLO stands for Main Lug Only, meaning this panelboard does not include a built-in main breaker. A separate upstream main disconnect or overcurrent protective device must be installed to protect this panel. This is common in commercial installations where the panel is fed from a switchboard or a dedicated disconnect enclosure. Your local electrical inspector or engineer can confirm the specific requirement for your installation.
This panel is designed for use with Eaton CH (Type-CH) bolt-on breakers rated for 347/600V service. Branch breakers must be appropriately rated for the 347/600V system voltage — not all standard residential or 120/240V CH breakers are suitable. Contact our team with your load schedule and we'll help identify the correct breakers for your circuit requirements.
Yes — this Eaton panelboard is rated for 347/600V, which is the standard three-phase distribution voltage widely used in Canadian commercial buildings and is compliant with Canadian system requirements. However, final installation must comply with the Canadian Electrical Code (CEC) and applicable local amendments. Always verify with your authority having jurisdiction (AHJ) before installation.