The NRS30 – GOULD 30A 600V CLASS K5 ONE-TIME FUSE is designed for reliable circuit protection in various electrical applications. This high-quality fuse ensures safety and performance, providing 30 amps of protection at 600 volts. Ideal for industrial and commercial use, it effectively prevents overloads and short circuits, maintaining system integrity.
| Brand | Gould |
|---|---|
| Amperage | 30 A |
| Voltage | 600V |
| Interrupting Rating | 10 kA |
| Frame / Series | NRS |
| Catalogue # | NRS30 |
The Gould NRS30 is a 30A, 600V, Class K5 one-time (non-renewable) fuse with a 10kA interrupting rating. Class K5 fuses fit standard Class H/K fuse holders and disconnects rated for 30A, 600V — commonly used in fusible safety switches, motor circuits, and industrial control panels. Because this is a one-time fuse, it must be replaced (not re-fusible) after operation; equivalent replacements include other Class K5 or Class H 30A 600V cartridge fuses in the same physical dimensions (Dimensions: 1-1/16" × 5", 30A cartridge size). Send us your fuse holder or disconnect model and we'll confirm compatibility.
A Class K5 one-time fuse like the NRS30 is a non-renewable cartridge fuse: once it opens, the entire fuse must be replaced. Class RK5 fuses have the same voltage and current ratings but feature a rejection feature (notched ferrule) that prevents them from being installed in non-rejection holders, offering better short-circuit protection. While a Class K5 fuse will physically fit a standard (non-rejection) Class H/K holder, a Class RK5 fuse will not fit a non-rejection holder. Always verify your holder type before substituting. Contact our team if you need help selecting the right replacement.
The Gould NRS series is considered a legacy/obsolete product line. Northern Breaker Group specializes in sourcing hard-to-find and obsolete fuses like the NRS30. Direct equivalents are typically 30A, 600V, Class K5 one-time cartridge fuses from other manufacturers (such as the Ferraz Shawmut/Mersen NRS30 or equivalent). We maintain stock of obsolete Gould fuses — contact us or visit one of our Calgary, Edmonton, or Vancouver counters for current availability.
The NRS30 is suitable for general-purpose overcurrent protection in industrial and commercial applications up to 600V AC, including branch-circuit protection, feeder circuits, motor branch circuits (as a branch-circuit fuse, not motor-rated), lighting panels, and control circuits. Its 10kA interrupting rating means it is designed for systems where available fault current does not exceed 10,000 amperes. For applications with higher available fault current, a higher interrupting-rated fuse (such as Class RK1 or Class J) should be considered.